CLEAR WIDTH — 10'-0" TO 20'-0"CLEAR HEIGHT — 8'-0" TO 14'-0"2" PANELTHICKNESSWEATHERSEALFULL RISE4 SECONDSDOCK SYSTEMS INC. — ENGINEERING ELEVATION — DWG-SD-001

Industrial Dock Systems · Est. 1988 · Dallas, TX

Engineered to Open.
Built to Hold.

Sectional dock doors, levelers, and weather seals — specified to the inch, rated to the wind load, ready for the coldest chain you run.

IDA Certified InstallerUL 325 ListedANSI/DASMA 102 CompliantWind Load Rated to 130 MPHR-Value Up to 17.8250,000 Cycle RatingCold Chain CertifiedTexas DOT ApprovedLEED Contribution Points AvailableSame-Day Field MeasurementIDA Certified InstallerUL 325 ListedANSI/DASMA 102 CompliantWind Load Rated to 130 MPHR-Value Up to 17.8250,000 Cycle RatingCold Chain CertifiedTexas DOT ApprovedLEED Contribution Points AvailableSame-Day Field Measurement
Engineering Detail

Every component
drawn before it's drilled.

TRACK HEIGHT 14-GA. GALV. STEEL
Zone 01 — Track Assembly
Zone 01 — Track Assembly

Galvanized Steel Track

Precision-formed, zero-deflection

Cold-rolled 14-gauge galvanized steel track channels, radius-bent to ±0.015″ tolerance. Vertical and horizontal sections bolt together with 3/8″ carriage bolts at 24″ O.C. — no field welding, no shimming.

14-ga. galvanized steel2″ × 3″ track profileContinuous angle strut±0.015″ radius tolerance
Close-up of galvanized steel track assembly with bolt connections on industrial loading dock door
2″ 26-GA. STEEL FACING CFC-FREE PU FOAM CORE R-17.8 · 2.2 LB/FT³ DENSITY
Zone 02 — Panel Cross-Section
Zone 02 — Panel Cross-Section

2″ Insulated Panel

CFC-free polyurethane core

Two-inch thick steel-faced sandwich panels with CFC-free polyurethane foam injected at 2.2 lbs/cu.ft. density. Tongue-and-groove joint seals panel-to-panel gaps to 0.003″ — the difference between R-17.8 and losing your cold chain at 3 AM.

2″ panel thicknessR-17.8 insulation value26-ga. galvanized facingsCFC-free polyurethane core
Cross-section view of insulated steel panel showing polyurethane foam core layers
4″ COMP. EPDM FOAM TRAILER FACE
Zone 03 — Dock Seal Profile
Zone 03 — Dock Seal Profile

Compression Dock Seal

Cold-chain rated to −40°F

Extruded EPDM foam seal compresses to 4″ minimum against trailer face. Maintains positive contact across ±8″ of lateral trailer wander. Rated to −40°F continuous service — holds your cold chain through a Texas August at the trailer threshold where other seals fail.

EPDM foam extrusion−40°F service rating±8″ lateral tolerance4″ minimum compression
EPDM dock seal compression profile against trailer face showing weather sealing contact
Engineering Specifications

Numbers that belong
on the submittal.

Download Full Submittal
ParameterValueNote
Panel Thickness2.0″Nominal — steel-faced sandwich
Insulation R-ValueR-17.8CFC-free polyurethane foam, 2.2 lb/ft³
Steel Gauge — Facing26 ga.Galvanized per ASTM A653 G90
Track Gauge14 ga.Cold-rolled, hot-dip galvanized
Wind Load Rating130 MPHASCE 7-22, Exposure C — standard
Cycle Life Rating250,000Full open-close cycles, DASMA 102
Full Rise Time4 sec.At 10 FPM motor speed, 10×10 door
Clear Width Range8′–0″ to 20′–0″Custom widths available
Clear Height Range8′–0″ to 14′–0″Custom heights to 20′ available
Seal Service Temp.−40°FContinuous EPDM seal rating
Lateral Seal Tolerance±8″Trailer wander accommodation
Motor Options1/2 – 1 HP115V/1Ph, 208-230V/1Ph, 460V/3Ph
UL ListingUL 325Monitored entrapment protection
StandardANSI/DASMA 102Sectional door performance standard
Specifications reflect standard product. Custom wind load ratings, R-values, and dimensions available. Contact engineering for project-specific submittals.
UL 325 Listed
ANSI/DASMA 102
ASCE 7-22 Wind Load
ASTM A653 G90
IDA Certified
Product Line

Three components.
One loading bay.

Industrial sectional dock door in galvanized steel with multiple panels closed on loading bay
Primary Product

SD-Series Sectional Door

The door that earns its spec sheet.

Cold-rolled steel track, 2″ insulated panels, torsion spring counterbalance. Rises in 4 seconds. Rated for 250,000 cycles. Available in 57 standard colors and custom RAL.

4 secRise Time
250KCycle Life
17.8R-Value
130 MPHWind Load
Configure This Door
Hydraulic dock leveler bridging gap between loading dock and trailer bed
Dock Equipment

DL-400 Hydraulic Leveler

Trailer bed to concrete — zero lip.

Hydraulic actuated dock leveler with 20,000 lb. capacity. 6″ above / 12″ below dock range. Automatic lip extension holds contact across full range of trailer heights.

20K lbCapacity
+6/-12″Range
6′–8′Width
< 30 secCycle
Specify Leveler
EPDM foam dock seal compressed against trailer face on loading dock
Weather Sealing

CS-200 Compression Seal

Cold chain doesn't negotiate.

EPDM foam compression seal rated to −40°F. 4″ minimum compression. Accommodates ±8″ lateral trailer wander. Maintains positive contact across the full trailer height range.

−40°FTemp. Rating
4″ minCompression
±8″Lateral
EPDMMaterial
Select Seal Type
Field Reports

The numbers come from
people with deadlines.

40 baysNew DC Installation

We spec'd forty bays on the new Laredo distribution center. Dock came back with submittals in 36 hours, stamped and ready for the city. No other manufacturer even came close on turnaround.

Marcus Whitfield

Director of Logistics Infrastructure

Southwest Cold Chain Partners

18 hrsDoor-to-Door Replacement

Third door we had hit by a forklift in two years. Called Dock at 6 AM on a Tuesday. Field measurement by noon, new door on order same day. Back in operation Wednesday morning. That's what cold chain needs.

Teresa Galindo

Facilities Manager

Rio Grande Produce Distribution

140°F deltaSeal Temperature Hold

The CS-200 seals hold −20°F inside with Texas August outside. That's a 140-degree delta across a rubber gasket. We've run them two years without a single seal failure.

Jim Kowalski

Plant Engineering Manager

Lone Star Frozen Foods, Amarillo

Door Configurator

Configure Your Door

Four steps. Live price estimate. No email required to start.

Door Dimensions

Running Estimate
Width10'-0"
Height10'-0"
InsulationR-6.3
Wind Load90 MPH
Quantity1 door
Estimated Total
$3,600

USD · FOB Dallas, TX · Installed pricing available

Estimate based on standard product. Final price confirmed after field measurement and engineering review.

Request Submittal Package
For General Contractors

Submittals by Thursday.

Stamped engineering drawings, cut sheets, wind load calculations, and product data sheets — formatted for city review and AHJ submission. Tell us your jurisdiction and project schedule.

Engineering Drawings

Stamped elevation drawings, section cuts, hardware schedule — ready for AHJ.

Wind Load Calculations

ASCE 7-22 calculations signed by PE, jurisdiction-specific exposure category.

Product Data Sheets

Full cut sheets with dimensions, materials, finishes, and accessories.

Cycle Life Documentation

DASMA 102 test reports and 250,000-cycle certification for spec compliance.

Configure Your Door First

Need it faster? +1 (214) 555-0192 · Dallas engineering office · Mon–Fri 6 AM–6 PM CT